CF unit formatter incompatible with latest pint #522
With pint 0.24, the formatting machinery changed a lot. In 0.24.0 our formatter broke because we couldn't re-create Unit object, the registry was None (see hgrecco/pint#2009), this was fixed, but another bugfix broke the specific case of a dimensionless variable, see hgrecco/pint#2024.
I realized our method was a bit complicated and could be made simpler using pint formatting tools instead of regex. However, I haven't found a solution that was backwards-compatible. Here are 3 solutions I found:
frompint.delegates.formatter.plainimportDefaultFormatterfrompint.delegates.formatter._compound_unit_helpersimportprepare_compount_unitfrompintimportformatterclassCFUnitFormatter(DefaultFormatter):
defformat_unit(self, unit, uspec, sort_func, **babel_kwds):
numerator, denominator=prepare_compount_unit(
unit,
"~D",
sort_func=sort_func,
**babel_kwds,
registry=self._registry,
)
out=formatter(
numerator,
denominator,
as_ratio=False,
product_fmt=" ",
power_fmt="{}{}",
parentheses_fmt=r"{}",
)
out=out.replace("Δ°", "delta_deg")
returnout.replace("percent", "%")`
# Add to the registryunits.formatter._formatters['cf'] =CFUnitFormatter
Pro : User code does not need modification.
Con : Requires pinning pint >=0.24, will break eventually when prepare_compount_unit is modified (see comment in issue).
Simpler custom function
@pint.register_unit_format("cf")defshort_formatter(unit, registry, **options):
num= [(u, e) foru, einunit.items() ife>=0]
den= [(u, e) foru, einunit.items() ife<0]
# in pint < 0.24, the first argument of `formatter` is num + den# a test with packaging.version could make this work for all pint versionsout=formatter(
num,
den,
as_ratio=False,
product_fmt="{} {}",
power_fmt="{}{}"
)
out=out.replace("Δ°", "delta_deg")
returnout.replace("percent", "%")
The trouble here is that we don't have control on the "shortening" of the units. What was previously f"{u:cf}" must become f"{u:~cf}". And (of course!) f"{u:~cf}" will not work with previous versions of cf_xarray.
Pro : Simple. Could be made to work with previous versions of pint by.
Con : Requires users to change their code.
Hack and forget
Simply fix the dimensionless issue and don't think about it anymore.
@pint.register_unit_format("cf")defshort_formatter(unit, registry, **options):
importre# avoid issue in pint >= 0.24.1unit=unit._units.__class__({k.replace('dimensionless', ''): vfork, vinunit._units.items()})
# convert UnitContainer back to Unitunit=registry.Unit(unit)
# Print units using abbreviations (millimeter -> mm)s=f"{unit:~D}"# Search and replace patternspat=r"(?P<inverse>(?:1 )?/ )?(?P<unit>\w+)(?: \*\* (?P<pow>\d))?"defrepl(m):
i, u, p=m.groups()
p=por (1ifielse"")
neg="-"ifielse""returnf"{u}{neg}{p}"out, n=re.subn(pat, repl, s)
# Remove multiplicationsout=out.replace(" * ", " ")
# Delta degrees:out=out.replace("Δ°", "delta_deg")
returnout.replace("percent", "%")
Pro: Only fails with 0.24.0, User code needs not be changed.
Should gives the same result as before for all versions of pint (except 0.24.0, of course). In pint < 0.24, a dimensionless unit will yield "dimensionless" because in the older pints, the custom formatter isn't even called in that case. In pint 0.24.1, this was modified and the special case is managed at the beginning of this proposition.
I am using packaging.version.Version to ensure backward compatibility, which is not the elegantest but seems fine. Also, I assumed it was reasonable to use the "private" function registry._get_symbol.
The delta_deg has to do with https://pint.readthedocs.io/en/stable/user/nonmult.html, i.e. when two temperatures are subtracted, the result is not a temperature but rather a "delta". And the short symbol for that is the greek letter.
Both "Δ°C" and "delta_degC" are not recognized by udunits, so my guess is that this is to avoid unicode problems down the line in a netCDF ?
I recently stumbled upon these delta in xclim and I added an automatic translation into the related absolute unit in the specific function. (Δ°C -> K, Δ°F -> °R) But maybe that's a bit too strong for cf-xarray...
Activity
aulemahal commentedon Jun 28, 2024
I realized our method was a bit complicated and could be made simpler using pint formatting tools instead of regex. However, I haven't found a solution that was backwards-compatible. Here are 3 solutions I found:
Custom formatter class
Idea suggested by @hgrecco
prepare_compount_unitis modified (see comment in issue).Simpler custom function
The trouble here is that we don't have control on the "shortening" of the units. What was previously
f"{u:cf}"must becomef"{u:~cf}". And (of course!)f"{u:~cf}"will not work with previous versions ofcf_xarray.Hack and forget
Simply fix the dimensionless issue and don't think about it anymore.
aulemahal commentedon Jun 28, 2024
I found something that works in all cases!
Should gives the same result as before for all versions of pint (except 0.24.0, of course). In pint < 0.24, a dimensionless unit will yield
"dimensionless"because in the older pints, the custom formatter isn't even called in that case. In pint 0.24.1, this was modified and the special case is managed at the beginning of this proposition.I am using
packaging.version.Versionto ensure backward compatibility, which is not the elegantest but seems fine. Also, I assumed it was reasonable to use the "private" functionregistry._get_symbol.dcherian commentedon Jun 28, 2024
Nice work! Happy to merge this change. Let's also add a
pint!=0.24.0version pin.Just curious, why
out = out.replace("Δ°", "delta_deg")aulemahal commentedon Jun 28, 2024
The
delta_deghas to do with https://pint.readthedocs.io/en/stable/user/nonmult.html, i.e. when two temperatures are subtracted, the result is not a temperature but rather a "delta". And the short symbol for that is the greek letter.Both "Δ°C" and "delta_degC" are not recognized by udunits, so my guess is that this is to avoid unicode problems down the line in a netCDF ?
I recently stumbled upon these delta in xclim and I added an automatic translation into the related absolute unit in the specific function. (
Δ°C -> K,Δ°F -> °R) But maybe that's a bit too strong for cf-xarray...dcherian commentedon Jun 28, 2024
Let's add that as a comment in the code when you send in your PR.