You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
usage history: thinning drops a clock step-back smaller than 15 min #37
apps/server/src/usage/UsageReadingsHistory.ts:276-286: when the clock steps back by less than the thin interval (15 min), thinning removes the segment break. The PR body says readings after a step back are never thinned against the ones before it; that holds only for steps of 15 min or more. Harm is small (time error at most the step). Fix: keep the reading on each side of a segment break when thinning, plus a test.
From the round-4 check of #24 (#24 (comment)). Left as a minor at merge.
Activity
usage history: keep clock step-backs through thinning; test clock gua…
usage history: keep clock step-backs through thinning; test clock gua…
usage history: keep clock step-backs through thinning; test clock gua…