Skip to content

usage history: thinning drops a clock step-back smaller than 15 min #37

Closed

Description

@scuttletoby

apps/server/src/usage/UsageReadingsHistory.ts:276-286: when the clock steps back by less than the thin interval (15 min), thinning removes the segment break. The PR body says readings after a step back are never thinned against the ones before it; that holds only for steps of 15 min or more. Harm is small (time error at most the step). Fix: keep the reading on each side of a segment break when thinning, plus a test.

From the round-4 check of #24 (#24 (comment)). Left as a minor at merge.

🤖 Generated with Claude Code

Activity

  1. added 3 commits that reference this issue on Nov 18, 2026
    a0bdba9
    e2941a3
    ac0473e
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment