Skip to content
jefflaplantePublic

About

Lux - an EG4 inverter communications CLI with a publishing facility to MQTT

Resources

Stars

2 stars

Watchers

1 watching

Forks

Latest commit

 

History

20 Commits

Folders and files

Repository files navigation

EG4 Modbus — Direct Inverter Control for Conduit

A Go library and Conduit skill for direct Modbus communication with the EG4 18kPV inverter via the WiFi dongle's TCP port 8000.

Goal

Read and write inverter registers — battery charge/discharge schedules, modes, power limits — without depending on SolarAssistant, lxp-bridge, or the EG4 cloud.

Architecture

CLI / Library
  └── eg4-modbus Go library
        └── TCP:8000 → WiFi Dongle → RS485/Modbus RTU → EG4 18kPV Inverter

The library handles the LuxPower wire protocol (TCP framing around Modbus RTU). The Conduit skill exposes high-level actions like set_charge_schedule, get_battery_status, set_mode.

Status

Phase: Research & Design — protocol fully reverse-engineered from lxp-bridge source.

Breaking changes

  • lux write / set-mode / set-schedule: a declined or non-interactive confirmation now exits nonzero (cancelled at confirmation prompt). Previously --json with a closed stdin printed Cancelled. and exited 0, so automation could not distinguish a skipped write from a successful one. Scripts that rely on exit 0 must pass --yes explicitly.
  • The frozen-frame detector only observes input registers that feed a published topic. Blocks with no topic mapping are exempt by definition. (--stale-threshold 0 still disables the detector entirely.)

Key Documents

  • PROTOCOL.md — Full wire protocol specification
  • REGISTERS.md — Register map with read/write capabilities
  • DESIGN.md — Implementation plan and phasing