Repository navigation
Description
Stage A of #985. Plan: v2, section "Stages / A. Probes for claims 1 and 4 (audit doc)" — #985 (comment). The plan comment is authoritative; this restates it.
Builds: lem probes in a new workspace qa-h3-wangp-probes (H3 turbo, 960x544, 124 frames, seeds 1001 and 2002 per arm), written up in docs/proposals/audits/2026-10-h3-wangp-probes.md.
- Pinned configuration (Don, at approval): every job runs
weights_dtypeint8 and one fixed turbo-LoRA state (on or off, chosen before the first job). Each job'snoteand the audit doc state both, so a lip-sync verdict is not secretly a quantization verdict (idea: H3 audio refinement pass - lock the video latent, renoise audio at 0.5, 6 steps #984). - P1, lip-sync without
<d>(8 jobs): one person in frame, Ref2VA portrait +<Audio 1>, track held withhold_audio. Arm a: words in<d>. Arm b: no<d>; character named, "speaking/singing with natural lip movements synchronized", action limited to speaking. Each arm on a sung slice and a spoken line. - P4, FL2VA with a held song (4 jobs): arm a is
templates/minimax/image-to-videofl2va with a first frame +hold_audio; arm b is H3: test Ref2VA [keyframe completion + audio reuse] as a locked-frame shot that also lip-syncs to a song #852's Ref2VA[keyframe completion + audio reuse]route with the same picture and slice. Prompt follows P1's winning arm if known, else arm b. - Measures per job:
measure_syncagainst the source;templates/check-scriptor a transcription (did H3 voice its own words);get_output_framesat vocal onsets (mouth opens?); for P4, frame 0 against the input picture. - Verdicts: each claim confirmed, refuted or inconclusive.
Owes: the audit doc only, no code. Deploy: none (merge the doc to develop). Estimate: about $5 of session, about 90 GPU minutes on lem.
Passes when its own repro works — a results comment on #985 with one row per probe arm (verdict, job ids, measure_sync figure, observation); every cited job exists in qa-h3-wangp-probes, finished, has a note naming its arm, weights_dtype and turbo-LoRA state, and a get_job_workflow showing the arm's prompt, task type and hold_audio; all cited jobs share int8 and one turbo state; the audit doc on develop states the same verdicts and configuration; any probe not run is listed as not run with the reason — and every pending: #<this issue> case the tester writes passes.
Filed by claude-opus-5-5 via anthropic, decompose session for #985 plan v2.
Activity
dkackman commentedon Oct 25, 2026
Progress (build session,
claude-opus-5-5viaanthropic). No code; branchfeat/985-A-wangp-probeswill carry the audit doc.All probe jobs are queued in workspace
qa-h3-wangp-probes. Every job usesweights_dtypeint8 and has the turbo LoRA on.probes/wangp-p1-ref2va):d2384deebb50(done),f27b7a7af2233d9a4e7377fa,6d7f6faf8e608451e9fd9289,e0790f00b4c2c029d63a15e8,c0763cc81d6bd2384deebb50):probes/wangp-p4-fl2va):52195bad071b,db506b4f1049probes/wangp-p4-keyframe-ref2va):11eb727cd72d,3c097799d825Excluded:
423bcbe3c40f, a wiring job: it relabelled the 44.1 kHz slice as 48 kHz.dbcdd254f897, a prep job.Next: read the results and write the audit doc.
Merge feat/985-A-wangp-probes: #988 WanGP probes audit
dkackman commentedon Oct 25, 2026
Hand-off: stage A probes done
Feature lead:
claude-opus-5-5viaanthropic, build session, 2026-10-25.What shipped:
docs/proposals/audits/2026-10-h3-wangp-probes.md: commit a92c425 onfeat/985-A-wangp-probes, merged todevelop@ 31ab159.Plan items covered:
noteand in the doc.hold_audioagainst Ref2VA[keyframe completion + audio reuse].measure_sync;transcribe_audiowith word timestamps;Workflows (saved in
qa-h3-wangp-probes):probes/wangp-p1-ref2va;probes/wangp-p4-fl2va;probes/wangp-p4-keyframe-ref2va.Deviations (also in the doc):
Spoken slice rate: run with
sample_rate48000 against a 44100 Hz file, so it plays about 8.8% fast. Both arms got the same input.OOM reruns: three P4 jobs were SIGKILLed by host-RAM OOM when two workers ran at once. Each was rerun alone after
clear_memory. Only the reruns are cited:Excluded jobs, not results: 423bcbe3c40f (a wiring check) and dbcdd254f897 (prep transcription).
P4 prompt: in arm b style, because P1 had no winning arm (the plan's rule).
Claim 4 has no broken arm: it is applied as confirmed when both FL2VA seeds keep frame 0 and their mouths follow the track.
measure_syncanomaly: on the sung track,reference_secondsis 118.751 against a 5.17 s slice reference, with confidence 0.175 (sync_low_confidence). The figures are recorded as given and flagged for a follow-up. No verdict rests on them: underhold_audiothey compare audio to audio.dkackman commentedon Oct 25, 2026
Verify of stage #988 by the tester, claude-opus-5-5 via anthropic, against lem develop @ 31ab159. Outcome: M-F160 fails, so this goes back to owner:lead.
M-F158: pass.
list_jobsshows all 12 cited jobs succeeded inqa-h3-wangp-probes, with notes that name the arm, dtype and LoRA state. The three reruns are accounted for: f4fe60dcca4d, 422f22a7df71 and 8e42ec21cf9a.get_job_workflowon the cited jobs shows the shape the case asks for:hold_audio: previous_result:slice.<d>in P1a only; P4 prompts in P1b's form.M-F159: pass.
weights_dtype {int8}and the turbo LoRAlightx2v/Minimax-h3-Turbo.minimax_h3_ref2v_turbo_8step_v1.0_768p_bf16for the ref2va arms,minimax_h3_fl2v_turbo_4step_v1.2_768p_bf16for P4a (52195bad071b).M-F160: fail. I re-measured P4a seed 1001 (job 52195bad071b) with an inline
measure_syncworkflow (job db3c55bf7089, output since deleted):output:probes/wangp-p4-fl2va/20261025-153850-7c27a9b9/final/WanGPProbeFL2VA-shot.2-0.0.mp4.../intermediate/WanGPProbeFL2VA-slice.1-0.0.wavdevice: cpuThe result was
lag_seconds 0.0,confidence 0.171(below 0.3,sync_low_confidence),audio_seconds 5.1667,reference_seconds 118.751.The reading agrees with the record's 0.0 / 0.175 to within 0.05 s, so the record is honest. But the case's expected outcome is confidence ≥ 0.3, and an unreliable confidence is one of the findings the case lists. The record's ⚠ marks the same thing, on all three sung arms.
The cause looks like a server bug rather than a probe result. A 5.17 s slice reads as 118.751 s, which is the whole song, so the sung arms can't be judged until that's fixed. I filed it as #990 (owner:implementer). Once #990 is fixed, the sung sync figures need re-measuring and the record updating; the spoken arms (0.756) are fine.
To save the cap I didn't re-run the remaining 11 measurements or the P4a/P4b frame-0 checks once the case had failed.
The audit doc
docs/proposals/audits/2026-10-h3-wangp-probes.mdisn't served over MCP, so I can't check it from here. That's a matter for docs-review.The
pending: #988lines stay on M-F158, M-F159 and M-F160.Merge feat/985-A-wangp-probes: #988 sung sync re-measured
dkackman commentedon Oct 25, 2026
Bounce addressed: the sung sync figures were re-measured after #990.
What shipped:
The fix for the M-F160 failure:
reference_secondswas 5.1667, down from 118.751. That covers P1a/P1b sung and P4a/P4b.Why the 8 shots were re-measured, not re-generated: the bad slice only reached the
syncstep. Both of the model's audio inputs already cropped to the shot length (h3_hold_steps.py:219/236; diffusersbefore_encoder.py:370). Job 85fb684df2ef re-applied the fixed slice on cpu, then ranmeasure_synconce on each original job's output.Plan items covered: the audit doc and the #985 results comment, the same as the first hand-off.
Deviation: the sung sync figures come from a separate cpu job (85fb684df2ef), not from each probe job's own
syncstep. The doc records this as "Sung slice ran the whole song (#990)".— lead agent, claude-opus-5-5 via anthropic
dkackman commentedon Oct 25, 2026
Verified. Tester:
claude-opus-5-5viaanthropic, verify session, 2026-10-25, against lemdevelop@ 05e2f4d. I ran the stage's acceptance cases M-F158, M-F159 and M-F160 (regression-suite-model-specific.md) as written, over MCP. All three pass, and theirpending: #988lines are now removed.M-F158, the record and its jobs.
list_jobs(workspace="qa-h3-wangp-probes"): all 12 cited jobs aresucceeded, and each one's note names its arm and seed.get_job_workflow:<d>,hold_audio: previous_result:slice.<d>,hold_audioset.M-F159, one configuration.
weights_dtypeint8 with the turbo LoRA on: the ref2v 8-step file for P1 and P4b, the fl2v 4-step file for P4a.M-F160, the measurements reproduce.
measure_syncchain with freshslice_audioreferences: job 71058ee955ad, 12 steps, cpu, succeeded.get_output_frames(at=["frame:0"]):delete_output(job_id="71058ee955ad"). The workflow was inline, so there is no saved workflow to delete. The probe jobs are untouched.Not covered here: the audit doc
docs/proposals/audits/2026-10-h3-wangp-probes.mdisn't served over MCP, so these cases don't check its text.