Skip to content

Windows 11 clones park at the OOBE account screen: the clone's unattend has no AutoLogon #1092

Closed

Description

@Gerrrt

Symptom

After a domain rebuild, the two Windows 11 endpoints — carbuncle (154) and siren (155), cloned from template 911 — sit at the OOBE "set up a user account" screen and never reach a logon screen. The Server 2025 guests (DCs, titan, ramuh, from 912) are unaffected.

It is cosmetic, not a build failure

The rest of Setup completes and all automation runs; only the interactive OOBE front-end is stuck. On carbuncle, read through the guest agent while it was parked:

So the guest is fully domain-joined and reachable; what's wedged is the first-logon UX. It bites only when someone wants an interactive console/desktop on a Win11 endpoint (e.g. to run a collector locally) — there's no real user to log in as, and the parked page won't let you pick the built-in Administrator.

Root cause

scripts/sysprep.ps1 deliberately strips the build's autologon ("so nothing logs in on the generalised image"). The clone answer file packer/windows/unattend-oobe.xml.pkrtpl therefore has no <AutoLogon> — only HideLocalAccountScreen=true plus the enabled built-in Administrator.

On Windows 11 client, that is not enough to finish the OOBE account page: without an AutoLogon or a created local user, OOBE idles as defaultuser0. The build answer file (autounattend.xml.pkrtpl) completes precisely because it does carry <AutoLogon> (Administrator, LogonCount 1) — its own comment says "AutoLogon once is what runs bootstrap.ps1." Server 2025 OOBE proceeds to the logon screen without a user, so 912-based guests don't park.

Fix

Give the clone's oobeSystem a one-shot <AutoLogon> for Administrator (LogonCount 1), with FirstLogonCommands that turn autologon off and drop the plaintext DefaultPassword Setup writes to Winlogon. The generalised image still never autologins (sysprep.ps1 unchanged); only the clone's single OOBE pass does, then disables itself — mirroring the proven build path. Draft PR attached.

It needs a 911 template rebuild (packer build, ADR-0074) and a domain rebuild to take effect, which is the lab-pipeline flow's to run — hence the PR is a draft until a rebuilt 911 clone is seen landing at a normal logon screen.

Context: ADR-0074, #440, #774.

Found while trying to run a collector on carbuncle for #451.

Activity

  1. added
    bugSomething isn't working
    labstacks/lab on alexander (VLAN 30)
    on Oct 8, 2026
  2. Gerrrt commented on Oct 9, 2026

    @Gerrrt
    OwnerAuthor

    Verified on the rebuilt 911, 2026-10-09

    #1093 merged as ba39b65, and 911 was rebuilt from main (packer build -force, 1h15m). Then:

    • packer-smoke.sh 911 --keep: every check passed, including "Panther answer files scrubbed (Win clones leave the build password in plaintext at C:\Windows\Panther\unattend-original.xml, readable by Users #1099)".
    • The kept smoke clone (999), checked after first boot:
      • OOBEInProgress=0;
      • AutoAdminLogon=0;
      • no DefaultPassword in Winlogon;
      • defaultuser0 disabled;
      • Security log 4634 logoffs at 19:51:34–37Z;
      • quser: No User exists;
      • LogonUI is running and explorer isn't, so the console rests at the sign-in screen, not an unlocked desktop.
    • dot-windows (198), re-cloned from the new 911 with the targeted -replace: the same result on first boot, plus no Panther\unattend-original.xml.

    The chained single FirstLogonCommand (391863) is what ran. Closing.

    🤖 Generated with Claude Code

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment