You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Update newly added CLMU technote section with indoor humidity and air-conditioning dehumidification #4195
The code changes add indoor humidity and air-conditioning dehumidification to the CLMU BEM. It prognoses indoor specific humidity, calculates sensible cooling and latent dehumidification loads, and diagnoses condensate production and routes the condensate into urban runoff. The behavior is controlled by an integer CLM namelist variable, building_humidity_mode:
0: use the existing CLMU formulation without indoor humidity or AC dehumidification;
1: enable indoor humidity and latent heat exchange, but no AC dehumidification (requires prognostic building temperature, building_temp_method=1); and
2: enable indoor humidity, latent heat exchange, dehumidification load, and condensate production (requires prognostic building temperature, urban_hac to be ON or ON_WASTEHEAT and urban_explicit_ac=.true.).
The default is set to 0 to ensure bit-for-bit reproducibility with the original scheme.
Activity
[-]Update technote CLMU section: Indoor humidity and air-conditioning dehumidification[/-][+]Update newly added CLMU technote section with indoor humidity and air-conditioning dehumidification[/+]slevis-lmwg commentedon Oct 29, 2026
@olyson would you say that your PR #4270 fully resolves this issue, or only partly?
olyson commentedon Oct 30, 2026
Only partly...